June Promo — Ends June 30, 2026 | 20% Off Guardian Premium & Platform Only | Free Ground Shipping Included |
View Sale Prices →
Applications
Transcell’s single point load cells deliver accuracy for unevenly distributed, off-axis, and off-center loads. We offer a range of single-point load cells for use in many force measuring applications, including:
Retail and eCommerce Package Shipping
Postal Weighing
Parts Counting
Small Hopper Scales
Bench Scales, etc.
Features & Benefits
Aluminum Construction
Corrosion-Resistant
High Accuracy
High Stability
Easy to Install
Wide Capacity Range
Technical Specifications
View All Model Details
FA02 V18.11
FAA
FAK V18.5
FAK22 V20.8
FAS V18.4
FAS A4 V18.4
FAS (40-30kg)
FAS42 V19.4
FASB C4 V17.3
FASB V18.5
FASD V18.5
FAS-P V18.11
FATS V18.5
FAV V18.5
FAV60 V19.2
FAY
FSMD
FSMD2
FSS30 V19.4
FSSB V18.11
FSSB C4 V18.4
FSSV V18.5
FA02 V18.11
Specifications
Rated Output 1.0mV/V ± 0.05 mV/V
Zero Balance ± 0.1mV/V
Creep ± 0.05% of applied load
Nonlinearity ± 0.05 % of rated output
Hysteresis ± 0.05% of rated output
Repeatability ± 0.05% of rated output
Temp Effect on Output ± 0.05% of reading/10°C
Temp Effect on Zero ± 0.05% of output/10°C
Cable Length 0.25m [0.85ft]
Safe Temp Range -30 to +70°C
Temp Comp Range -10 to +40°C
Safe Overload 150% of capacity
Ultimate Overload 300% of capacity
Input Impedance 415 Ω
Output Impedance 350 Ω
Insulation Resistance 2000 MΩ
Rated Excitation 10 V DC/AC
Max Excitation 15 V DC/AC
FAA
Specifications
Rated Output 2.0mV/V ± 10%
Zero Balance ± 5% of rated output
Temp Effect on Output ± 0.002% of reading/°C
Cable Length 2m [6.76ft]
Safe Temp Range -30 to +70°C
Temp Comp Range -10 to +40°C
Safe Overload 150% of capacity
Ultimate Overload 300% of capacity
Input Impedance 406 Ω
Output Impedance 350 Ω
Insulation Resistance 2000 MΩ
Rated Excitation 10 V DC/AC
Max Excitation 15 V DC/AC
FAK V18.5
Specifications
Rated Output 2.0mV/V ± 10%
Zero Balance ± 3% of rated output
Creep ± 0.03% of applied load
Nonlinearity ± 0.03% of rated output
Hysteresis ± 0.03% of rated output
Repeatability ± 0.03% of rated output
Temp Effect on Output ± 0.002% of reading/°C
Temp Effect on Zero ± 0.002% of output/°C
Cable Length 13cm [0.43ft] / 35cm [1.15ft] / 275cm [9.02ft]
Safe Temp Range -10 to +70°C
Temp Comp Range -10 to +40°C
Safe Overload 150% of capacity
Input Impedance 410 Ω
Output Impedance 350 Ω
Insulation Resistance 5000 MΩ
Rated Excitation 10 V DC/AC
Max Excitation 15 V DC/AC
FAK22 V20.8
Specifications
Accuracy Class C2 C2.5 C3
Max Number of Intervals 2000 2500 3000
Y=Emax/vmin 4000 6000 7500
Z=Emax/(2*DR) 2000 2500 3000
Eccentric Loading Error(±%/cm) 0.0057 0.0042 0.0036
Sensitivity 2.00mV/V ±0.20mV/V
Zero Balance ±0.10mV/V
Maximum Platform 350x350mm
Safe Temp Range -30 to +70°C
Temp Comp Range -10 to +40°C
Safe Overload 150% of capacity
Ultimate Overload 300% of capacity
Rated Excitation 10 V DC/AC
Max Excitation 15 V DC/AC
Input Impedance 406 Ω
Output Impedance 350 Ω
Insulation Resistance 2000 MΩ
Compensation Circuit Type Balanced Bridge (+S)
Cable Length 420mm [1.38ft]
FAS V18.4
Specifications
Rated Output 2.0mV/V ± 10%
Zero Balance ± 3% of rated output
Creep ± 0.03% of applied load
Nonlinearity ± 0.03% of rated output
Hysteresis ± 0.03% of rated output
Repeatability ± 0.03% of rated output
Temp Effect on Output ± 0.002% of reading/°C
Temp Effect on Zero ± 0.002% of output/°C
Cable Length 2.75m [9.3ft]
Safe Temp Range -10 to +70°C
Temp Comp Range -10 to +40°C
Safe Overload 150% of capacity
Input Impedance 410 Ω
Output Impedance 350 Ω
Insulation Resistance 5000 MΩ
Rated Excitation 10 V DC/AC
Max Excitation 15 V DC/AC
FAS A4 V18.4
Specifications
Rated Output 2.0mV/V ± 10%
Zero Balance ± 3% of rated output
Creep ± 0.03% of applied load
Nonlinearity ± 0.03% of rated output
Hysteresis ± 0.03% of rated output
Repeatability ± 0.03% of rated output
Temp Effect on Output ± 0.002% of reading/°C
Temp Effect on Zero ± 0.002% of output/°C
Cable Length 2.75m [9.3ft]
Safe Temp Range -10 to +70°C
Temp Comp Range -10 to +40°C
Safe Overload 150% of capacity
Input Impedance 410 Ω
Output Impedance 350 Ω
Insulation Resistance 5000 MΩ
Rated Excitation 10 V DC/AC
Max Excitation 15 V DC/AC
FAS (40-30kg)
Specifications
Rated Output 2.0mV/V ± 10%
Zero Balance ± 10% of rated output
Creep ± 0.025% of applied load
Nonlinearity ± 0.03% of rated output
Hysteresis ± 0.03% of rated output
Repeatability ± 0.03% of rated output
Temp Effect on Output ± 0.0074% of reading/°C
Temp Effect on Zero ± 0.006% of output/°C
Cable Length 2m [6.76ft]
Safe Temp Range -30 to +70°C
Temp Comp Range -10 to +40°C
Safe Overload 150% of capacity
Ultimate Overload 300% of capacity
Input Impedance 415 Ω
Output Impedance 350 Ω
Insulation Resistance 2000 MΩ
Rated Excitation 10 V DC/AC
Max Excitation 15 V DC/AC
FAS42 V19.4
Specifications
Accuracy Class C3 C6
Max Number of Intervals 3000 6000
Y=Emax/vmin 7500 10000
Z=Emax/(2*DR) 3000 6000
Eccentric Loading Error 0.0057%/10°C 0.0024%/10°C
Sensitivity 2.00mV/V ±0.20mV/V
Zero Balance ±0.10mV/V
Safe Temp Range -30 to +70°C
Temp Comp Range -10 to +40°C
Safe Overload 150% of capacity
Ultimate Overload 300% of capacity
Rated Excitation 10 V DC/AC
Max Excitation 15 V DC/AC
Compensation Circuit Type Balanced Bridge
Input Impedance 406 Ω
Output Impedance 350 Ω
Insulation Resistance 2000 MΩ
Cable Length 2.0m [6.56ft]
FASB C4 V17.3
Specifications
Rated Output 2.0mV/V ± 10%
Zero Balance ± 3% of rated output
Creep ± 0.03% of applied load
Nonlinearity ± 0.03% of rated output
Hysteresis ± 0.03% of rated output
Repeatability ± 0.03% of rated output
Temp Effect on Output ± 0.002% of reading/°C
Temp Effect on Zero ± 0.002% of output/°C
Cable Length 10m [33.8ft]
Safe Temp Range -10 to +70°C
Temp Comp Range -10 to +40°C
Safe Overload 150% of capacity
Input Impedance 410 Ω
Output Impedance 350 Ω
Insulation Resistance 5000 MΩ
Rated Excitation 10 V DC/AC
Max Excitation 15 V DC/AC
FASB V18.5
Specifications
Rated Output 2.0mV/V ± 10%
Zero Balance ± 3% of rated output
Creep ± 0.03% of applied load
Nonlinearity ± 0.03% of rated output
Hysteresis ± 0.03% of rated output
Repeatability ± 0.03% of rated output
Temp Effect on Output ± 0.002% of reading/°C
Temp Effect on Zero ± 0.002% of output/°C
Cable Length 10m [33.8ft]
Safe Temp Range -10 to +70°C
Temp Comp Range -10 to +40°C
Safe Overload 150% of capacity
Input Impedance 410 Ω
Output Impedance 350 Ω
Insulation Resistance 5000 MΩ
Rated Excitation 10 V DC/AC
Max Excitation 15 V DC/AC
FASD V18.5
Specifications
Rated Output 1.0mV/V ± 1%
Zero Balance ± 1% of rated output
Creep ± 0.02% of applied load
Nonlinearity ± 0.02% of rated output
Hysteresis ± 0.02% of rated output
Repeatability ± 0.02% of rated output
Temp Effect on Output ± 0.02% of reading/°C
Temp Effect on Zero ± 0.02% of output/°C
Cable Length 2m [6.76ft]
Safe Temp Range -10 to +70°C
Temp Comp Range -10 to +40°C
Safe Overload 150% of capacity
Ultimate Overload 200% of capacity
Input Impedance 387 Ω
Output Impedance 350 Ω
Insulation Resistance 5000 MΩ
Rated Excitation 10 V DC/AC
Max Excitation 15 V DC/AC
FAS-P V18.11
Specifications
Rated Output 2.0mV/V ± 10%
Zero Balance ± 0.06mV/V
Creep ± 0.03% of applied load
Nonlinearity ± 0.03% of rated output
Hysteresis ± 0.03% of rated output
Repeatability ± 0.03% of rated output
Temp Effect on Output ± 0.002% of reading/°C
Temp Effect on Zero ± 0.002% of output/°C
Cable Length 1.5m [5.07ft]
Safe Temp Range -10 to +70°C
Temp Comp Range -10 to +40°C
Safe Overload 150% of capacity
Input Impedance 410 Ω
Output Impedance 350 Ω
Insulation Resistance 5000 MΩ
Rated Excitation 10 V DC/AC
Max Excitation 15 V DC/AC
FATS V18.5
Specifications
Rated Output 2.0mV/V ± 10%
Zero Balance ± 3% of rated output
Creep ± 0.02% of applied load
Nonlinearity ± 0.02% of rated output
Hysteresis ± 0.02% of rated output
Repeatability ± 0.02% of rated output
Temp Effect on Output ± 0.002% of reading/°C
Temp Effect on Zero ± 0.002% of output/°C
Cable Length 0.35m [1.18ft]
Safe Temp Range -10 to +70°C
Temp Comp Range -10 to +40°C
Safe Overload 150% of capacity
Input Impedance 410 Ω
Output Impedance 350 Ω
Insulation Resistance 5000 MΩ
Rated Excitation 10 V DC/AC
Max Excitation 15 V DC/AC
FAV V18.5
Specifications
Rated Output 2.0mV/V ± 10%
Zero Balance ± 3% of rated output
Creep ± 0.03% of applied load
Nonlinearity ± 0.03% of rated output
Hysteresis ± 0.03% of rated output
Repeatability ± 0.03% of rated output
Temp Effect on Output ± 0.002% of reading/°C
Temp Effect on Zero ± 0.002% of output/°C
Cable Length 6m [20.28ft]
Safe Temp Range -10 to +70°C
Temp Comp Range -10 to +40°C
Safe Overload 150% of capacity
Input Impedance 410 Ω
Output Impedance 350 Ω
Insulation Resistance 5000 MΩ
Rated Excitation 10 V DC/AC
Max Excitation 15 V DC/AC
FAV60 V19.2
Specifications
Y=Emax/vmin 3000 5400 12000
Z=Emax/(2*DR) 2000 2500 3000
Temp Effect on Output ± 0.014% of reading/10°C ± 0.010% of reading/10°C ± 0.010% of reading/10°C
Sensitivity 2.00mV/V ±0.20mV/V
Zero Balance ±0.10mV/V
Eccentric Loading Error 0.0057±%/cm
Safe Temp Range -30 to +70°C
Temp Comp Range -10 to +45°C
Safe Overload 150% of capacity
Ultimate Overload 300% of capacity
Rated Excitation 10 V DC/AC
Max Excitation 15 V DC/AC
Compensation Circuit Type Balanced Bridge
Input Impedance 408 Ω
Output Impedance 350 Ω
Insulation Resistance 2000 MΩ
Cable Length 3.0m [9.84ft]
FAY
Specifications
Rated Output 2.0mV/V ± 10%
Zero Balance ± 3% of rated output
Creep ± 0.03% of applied load
Nonlinearity ± 0.03% of rated output
Hysteresis ± 0.03% of rated output
Repeatability ± 0.03% of rated output
Temp Effect on Output ± 0.002% of reading/°C
Temp Effect on Zero ± 0.002% of output/°C
Cable Length 6.10m [20ft]
Safe Temp Range -10 to +70°C
Temp Comp Range -10 to +40°C
Safe Overload 150% of capacity
Input Impedance 410 Ω
Output Impedance 350 Ω
Insulation Resistance 5000 MΩ
Rated Excitation 10 V DC/AC
Max Excitation 15 V DC/AC
FSMD
Specifications
Minimum Load Cell Verification Interval (Vmin) ±2000 counts
Combined Error ±0.012%FS
Creep ±0.012%FS
Zero Balance, Raw Counts ±2000 increment
Output Resolution at Full Load, Raw Counts 256000 increment(10kg) / 512000 increment(15kg/20kg)
Internal AD Conversion Rate 1200upd./sec
Safe Load Limit 300%* Emax (10kg) / 150%* Emax (20kg-50kg)
Ultimate Load 600%* Emax (10kg) / 300%* Emax (20kg-50kg)
Temp Effect on Zero 0.001%FS/°C
Temp Effect on Output 0.001%FS/°C
Operating Temp Range -10 to +40°C
Storage Temp Range -40 to +70°C
EMC Performance Mid Class E2 (industrial locations)
Insulation Body/Electronics @ 500VDC 1000 MΩ
Vibration 2.5G operational; 5G non-operational
Corrosion Resistance All stainless steel (Electro polished)
Fix, Digital Low Pass IIR Filter, Default 18Hz (Suppress 50Hz and 60Hz influence)
Adjustable, Digital Low Pass IIR Filter 18-0.25; Selectable in 8 steps
Adjustable, Digital Low Pass FIR Filter 40-5; Selectable in 8 steps
Adjustable, External Output Update Rate 1200-9upd./sec; Selectable in 8 steps
FSMD2
Specifications
Minimum Load Cell Verification Interval (Vmin) Emax/10000
Combined Error ±0.017%FS
Creep ±0.017%FS
Zero Balance, Raw Counts ±2000 increment
Output Resolution at Full Load, Raw Counts 256000 increment(10kg) / 512000 increment(20kg/50kg)
Internal AD Conversion Rate 1200upd./sec
Safe Load Limit 300%* Emax (10kg) / 150%* Emax (20kg-50kg)
Ultimate Load 600%* Emax (10kg) / 300%* Emax (20kg-50kg)
Eccentric Loading Error Acc. ±0.0233%FS
Temp Effect on Zero 0.001%FS/°C
Temp Effect on Output 0.001%FS/°C
Operating Temp Range -10 to +40°C
Storage Temp Range -40 to +70°C
EMC Performance Mid Class E2 (industrial locations)
Insulation Body/Electronics @ 500VDC 1000 MΩ
Vibration 2.5G operational; 5G non-operational
Corrosion Resistance All stainless steel
Fix, Digital Low Pass IIR Filter, Default 18Hz (Suppress 50Hz and 60Hz influence)
Adjustable, Digital Low Pass IIR Filter 18-0.25; Selectable in 8 steps
Adjustable, Digital Low Pass FIR Filter 40-5; Selectable in 8 steps
Adjustable, External Output Update Rate 1200-9upd./sec; Selectable in 8 steps
FSS30 V19.4
Specifications
Accuracy Class C1 C3
Max Number of Intervals 1000 3000
Y=Emax/Vmin 2000 15000
Zero Return, 30 min. ±0.03% of applied load ±0.017% of applied load
Total Error (per OIML R60) ±0.05% of rated output ±0.02% of rated output
Temp Effect on Zero ±0.01% of rated output/°C ±0.0023% of rated output/°CV
Temp Effect on Output ±0.003% of applied load/°C ±0.001% of applied load/°C
Eccentric Loading Error ±0.0074% of rated load/cm ±0.0049% of rated load/cm
Rated Output 2.0mV/V±0.2mV/V
Zero Balance ±0.2mV/V
Recommended Torque 13N*m
Temp Comp Range -10 to +40°C
Safe Temp Range -20 to +70°C
Safe Overload 150% of capacity
Ultimate Overload 300% of capacity
Rated Excitation 10 V DC/AC
Max Excitation 15 V DC/AC
Input Impedance 385 Ω
Output Impedance 350 Ω
Insulation Resistance 2000 MΩ
Cable Length 1.5m [4.92ft]
FSSB V18.11
Specifications
Rated Output 2.0mV/V ± 0.1%
Zero Balance ± 3% of rated output
Creep ± 0.03% of applied load
Nonlinearity ± 0.03% of rated output
Hysteresis ± 0.03% of rated output
Repeatability ± 0.03% of rated output
Temp Effect on Output ± 0.002% of reading/°C
Temp Effect on Zero ± 0.002% of output/°C
Cable Length 6m [19.69ft], 10m [32.81ft]
Safe Temp Range -10 to +70°C
Temp Comp Range -10 to +40°C
Safe Overload 150% of capacity
Input Impedance 387 Ω
Output Impedance 350 Ω
Insulation Resistance 5000 MΩ
Rated Excitation 10 V DC/AC
Max Excitation 15 V DC/AC
FSSB C4 V18.4
Specifications
Rated Output 2.0mV/V ± 0.1%
Zero Balance ± 3% of rated output
Creep ± 0.03% of applied load
Nonlinearity ± 0.03% of rated output
Hysteresis ± 0.03% of rated output
Repeatability ± 0.03% of rated output
Temp Effect on Output ± 0.002% of reading/°C
Temp Effect on Zero ± 0.002% of output/°C
Cable Length 6m [19.69ft] / 10m [32.81ft]
Safe Temp Range -10 to +70°C
Temp Comp Range -10 to +40°C
Safe Overload 150% of capacity
Input Impedance 387 Ω
Output Impedance 350 Ω
Insulation Resistance 5000 MΩ
Rated Excitation 10 V DC/AC
Max Excitation 15 V DC/AC
FSSV V18.5
Specifications
Rated Output 2.0mV/V ± 0.1%
Zero Balance ± 1% of rated output
Creep ± 0.03% of applied load
Nonlinearity ± 0.03% of rated output
Hysteresis ± 0.03% of rated output
Repeatability ± 0.03% of rated output
Temp Effect on Output ± 0.02% of reading/°C
Temp Effect on Zero ± 0.02% of output/°C
Cable Length 2.5m [8.45ft]
Safe Temp Range -30 to +70°C
Temp Comp Range -10 to +40°C
Safe Overload 150% of capacity
Ultimate Overload 200% of capacity
Input Impedance 387 Ω
Output Impedance 350 Ω
Insulation Resistance 5000 MΩ
Rated Excitation 10 V DC/AC
Max Excitation 15 V DC/AC
IndustriesIndustries