CD-GD-GW Weighing Module
Weighing Mount with Canister-Style Load Cell and mV/V Output
Applications
Both the load cell and weighing module are stainless steel, making the CD-GD-GW Series ideal for weighing applications in harsh environments.
Purchase in Our Store
Need a Custom Solution?
Contact UsStainless Steel Construction
Includes Column-Type Load Cell
Conventional mV/V Output from Load Cell
6-Wire Output for Higher Accuracy over Long Cable Runs
Technical Specifications
View All Model Details
Insert Schematic Here
Specifications | |
---|---|
Rated Output | 2.0mV/V ± 0.1% |
Zero Balance | ± 1% of rated output |
Creep | ± 0.03% of applied load |
Nonlinearity | ± 0.03% of rated output |
Hysteresis | ± 0.03% of rated output |
Repeatability | ± 0.03% of rated output |
Temp Effect on Output | ± 0.002% of reading/°C |
Temp Effect on Zero | ± 0.002% of output/°C |
Cable Length | 13m [43.94ft] |
Safe Temp Range | -10 to +70°C |
Temp Comp Range | -10 to +40°C |
Safe Overload | 150% of capacity |
Input Impedance | 1120 Ω |
Output Impedance | 1000 Ω |
Insulation Resistance | 5000 MΩ |
Rated Excitation | 10 V DC/AC |
Max Excitation | 15 V DC/AC |